How many cfm does an HRV or ERV need? Floor area and bedrooms in, the IRC or ASHRAE 62.2 rate out, raised for part-time running and bathroom pickups, plus what the core saves.
HRV Sizing Calculator - CFM for an HRV or ERV
How many cfm does an HRV or ERV need? Floor area and bedrooms in, the IRC or ASHRAE 62.2 rate out, raised for part-time running and bathroom pickups, plus what the core saves.
Parameters
Enter data for calculations
💡 Fill in all required fields to unlock the calculate button
HRV and ERV size in cfm, from the code that applies to your house
Floor area and bedrooms decide most of it. This HRV sizing calculator turns them into the balanced airflow a heat recovery or energy recovery ventilator has to move, under the IRC table and equation or under ASHRAE 62.2, then checks whether bathroom pickups or part-time running push the number higher. A 2,400 sq ft house with 3 bedrooms needs 54 cfm under the IRC equation and 102 cfm under ASHRAE 62.2.
The problem: two published rules, one house, two answers almost twice apart. Buy a unit for the smaller one and it falls short wherever ASHRAE 62.2 is the rule. Buy for the larger one and you may pay for a box and ducts sized for air the local code never asked for.
The way out: find out which rule your building department or your energy program enforces, size to that one, and then let the two checks that can only raise the number (part-time operation and bathroom exhaust) have their say. The calculator does all three and shows each step.
From floor area to bathroom grilles
- Conditioned floor area - square feet inside the heated and cooled envelope. Leave out an unconditioned garage or attic.
- Bedrooms - the rules use bedrooms plus one as the expected number of people. A studio counts as one bedroom.
- Ventilation rule - IRC (Section M1505.4.3 of the model residential code) or ASHRAE 62.2 (the ventilation standard some energy programs and local amendments cite).
- Occupants (ASHRAE only, optional) - if more people live there than bedrooms plus one, each extra person adds 7.5 cfm.
- Run time (IRC only) - continuous, or a share of every 4-hour period. Less run time means a higher rate while running.
- Bathrooms on the ventilator - how many bathrooms the unit exhausts from instead of a bath fan. Each needs 20 cfm when the unit runs all the time.
- Heat recovery (optional) - the sensible recovery efficiency from the unit's listing, the outdoor design temperature, heating degree days, gas price and furnace efficiency, to see what the core saves.
IRC or ASHRAE 62.2: which number to size for
Both rules start from the same 7.5 cfm per person. The difference is the area term: 0.01 cfm per square foot in the IRC equation against 0.03 cfm in ASHRAE 62.2. On a big house that gap dominates. The figures below come straight from the calculator, continuous operation, no bathroom pickups.
| House | IRC equation | IRC table | ASHRAE 62.2 |
|---|---|---|---|
| 900 sq ft, 1 bedroom | 24 | 30 | 42 |
| 1,525 sq ft, 2 bedrooms | 37.8 | 60 | 68.3 |
| 2,400 sq ft, 3 bedrooms | 54 | 60 | 102 |
| 3,500 sq ft, 4 bedrooms | 72.5 | 90 | 142.5 |
| 5,000 sq ft, 5 bedrooms | 95 | 105 | 195 |
The IRC lets you use either its table or its equation, so the calculator takes the lower of the two. The table works in floor-area bands (up to 1,500 sq ft, 1,501 to 3,000 and so on) and bedroom pairs, which is why it sometimes lands well above the equation, as on the 1,525 sq ft house that just crosses into the second band. The ASHRAE figure for that house, 68.25 cfm, is the worked example ACCA published for the formula.
Three things that push the airflow up
Running part of the time. The IRC allows a ventilator on a timer if it moves more air while it is on. Table M1505.4.3(2) gives the multiplier: 1.3 at 75% run time, 1.5 at 66%, 2 at 50%, 3 at 33% and 4 at 25% of each 4-hour period. The 2,400 sq ft house goes from 54 cfm continuous to 108 cfm at half time and 162 cfm at a third.
Bathrooms on the ventilator. A bathroom needs 20 cfm of continuous exhaust or 50 cfm intermittent. When the HRV or ERV replaces the bath fans, its exhaust side has to cover 20 cfm per bathroom. A 1,200 sq ft, 2 bedroom house under the IRC needs only 34.5 cfm for the whole house, but with three bathroom pickups the unit has to move 60 cfm.
More people than bedrooms. Under ASHRAE 62.2 a known occupancy above bedrooms plus one adds 7.5 cfm a head. A 1,800 sq ft, 3 bedroom house is 84 cfm for four people and 99 cfm for six.
Matching the result to your job
| Your situation | Size for |
|---|---|
| Local code follows the IRC, no energy program | The IRC result, continuous operation |
| Energy program or local amendment cites ASHRAE 62.2 | The ASHRAE result, unless a blower door test earns a credit |
| Unit on a timer or cycling with the furnace fan | The run-time line, which can be two to four times the continuous rate |
| Ventilator replaces the bath fans | At least 20 cfm per bathroom on the exhaust side, running continuously |
| Two candidate units both clear the number | Compare rated airflow at your real duct static pressure, not the free-air maximum on the box |
What the heat recovery core is worth
Every cubic foot of outdoor air has to be heated to room temperature, at 1.08 Btu/hr per cfm per degree F. The core hands part of that back from the stale air on its way out; the share is the sensible recovery efficiency (SRE) printed in the unit's listing. Enter it and the calculator shows both the design-day load and the season.
Fresh air needs 7,160 Btu/hr to reach 70 F; the core returns 5,370 Btu/hr.
119 therms of heat kept, about $188 a year with a 95% furnace at $1.50 a therm.
2,843 Btu/hr on the design day and about $99 a year: half the air, half the saving.
The savings leave out the electricity the two fans use, defrost cycles in deep cold and duct losses, so treat them as the ceiling of what the core can do.
HRV sizing questions
Related tools
Radiant Floor Heating Calculator
Btu per sq ft, floor surface temperature, feet of PEX and circuits for a room - See the calculator
Heat Loss Calculator
Design heat loss of a room or house in Btu/hr, air leakage line included - See the calculator
Baseboard Heat Calculator
Feet of hot water or electric baseboard for a room from its heat loss - See the calculator
Insulation Calculator
How much insulation the walls or attic need - See the calculator
Chimney Draft Calculator
Draft for a stove or fireplace, which a tight, ventilated house can weaken - See the calculator
Gas Bill Calculator
Monthly gas cost from usage and rates - See the calculator
Heat Pump COP Calculator
Efficiency of a heat pump at a given outdoor temperature - See the calculator
Air Conditioner Size Calculator
Cooling capacity for the same house, in Btu and tons - See the calculator