How many feet of baseboard does the room need? Enter its heat loss in Btu/hr and get the length of hot water baseboard at your water temperature, or the watts, feet and amps of electric heat.
Baseboard Heat Calculator - Feet of Hydronic or Electric
How many feet of baseboard does the room need? Enter its heat loss in Btu/hr and get the length of hot water baseboard at your water temperature, or the watts, feet and amps of electric heat.
Parameters
Enter data for calculations
💡 Fill in all required fields to unlock the calculate button
How many feet of baseboard heat a room needs
Type the room heat loss in Btu per hour, choose hot water or electric baseboard, and this baseboard heat calculator returns the length to install. For hot water it reads the manufacturer's rating at your water temperature; for electric it converts to watts, feet, amps and heater sizes. A room losing 6,000 Btu/hr needs 11 ft of hot water baseboard at 180 F, 20 ft at 140 F, or 1,758 W of electric heat, about 8 ft at 240 V.
Add the free wall length under windows and along outside walls and the result also says whether the baseboard fits.
Three answers and two choices
- Room heat loss - Btu/hr for this room at the design temperature. Work it out room by room with a heat loss calculator; a whole-house figure divided by the floor area misses corner rooms and big windows.
- Hot water or electric - hydronic baseboard fed by a boiler, or electric baseboard heaters wired to a circuit.
- Water temperature and flow (hot water) - the average of supply and return, 110 to 220 F. 1 gpm unless the loop is known to carry 4 gpm or more.
- Voltage (electric) - 240 V in most houses, 208 V in many apartment buildings.
- Free wall (optional) - feet of wall where baseboard can go, usually under windows and along outside walls.
The hot water ratings, temperature by temperature
The calculator uses Slant/Fin's published ratings for its Fine/Line 30 baseboard with a 3/4 in. element: Btu/hr per foot of finned length, with 65 F air entering at the bottom and the 15% heating effect factor included. The right-hand columns show what the same 6,000 Btu/hr room needs at each temperature.
| Average water | 1 gpm | 4 gpm | Active ft, 6,000 Btu/hr | Baseboard to buy |
|---|---|---|---|---|
| 110 F | 160 | 160 | 37.5 | 38 ft |
| 120 F | 210 | 220 | 28.6 | 30 ft |
| 130 F | 260 | 270 | 23.1 | 24 ft |
| 140 F | 320 | 340 | 18.8 | 20 ft |
| 150 F | 380 | 400 | 15.8 | 17 ft |
| 160 F | 450 | 480 | 13.3 | 14 ft |
| 170 F | 510 | 540 | 11.8 | 13 ft |
| 180 F | 580 | 610 | 10.3 | 11 ft |
| 190 F | 640 | 680 | 9.4 | 10 ft |
| 200 F | 710 | 750 | 8.5 | 9 ft |
| 210 F | 770 | 810 | 7.8 | 9 ft |
| 215 F | 810 | 860 | 7.4 | 8 ft |
| 220 F | 840 | 890 | 7.1 | 8 ft |
Two patterns stand out. Output falls faster than the temperature: going from 180 F to 140 F, a cut of under a quarter, takes away 45% of the output (580 to 320). And the 4 gpm column barely helps, so the manufacturer allows it only when the flow is known to reach 4 gpm. Other baseboards and the 1/2 in. element rate differently, so use the table for the model you buy.
Rooms by heat loss, sorted by what they need
A corner bedroom with heated rooms above and below. Hot water at 180 F: 4 ft (3.0 ft active). Electric: 508 W, about 3 ft.
Hot water at 180 F: 6 ft (5.2 ft active). One 4 ft electric heater at 240 V gives 3,412 Btu/hr and covers it.
Hot water: 11 ft at 180 F, 30 ft at 120 F. Electric: 1,758 W, 8 ft at 240 V or 10 ft at 208 V.
Hot water: 17 ft at 180 F (15.5 ft active), 21 ft at 160 F.
Electric: 3,517 W, about 15 ft at 240 V and 14.7 A; the circuit is sized for 125% of that.
Electric baseboard heater sizes at 240 V and 208 V
Wattage per foot comes from a common 4 ft heater rated 1,000 W at 240 V and 750 W on 208 V. A heater's output falls with the square of the voltage, which is why the same unit loses a quarter of its heat on a 208 V supply.
| Length | W at 240 V | Btu/hr at 240 V | W at 208 V | Btu/hr at 208 V |
|---|---|---|---|---|
| 2 ft | 500 | 1,706 | 375 | 1,280 |
| 4 ft | 1,000 | 3,412 | 750 | 2,559 |
| 6 ft | 1,500 | 5,118 | 1,125 | 3,839 |
| 8 ft | 2,000 | 6,824 | 1,500 | 5,118 |
Some models pack more watts into the same length, so read the label: the calculator's foot count assumes 250 W per foot at 240 V. The National Electrical Code treats fixed electric space heating as a continuous load, so the branch circuit is sized for 125% of the heaters' current.
Why active length is shorter than the cover
Hot water ratings are per foot of finned element, which stops 5 to 6 in. short of the overall length of the enclosure. The calculator divides the heat loss by the rating to get the finned length, adds half a foot and rounds up to a whole foot, the way baseboard is sold. On runs broken into several pieces, each piece loses its own unfinned ends, so allow a little more.
Questions about sizing baseboard
Related tools
Heat Loss Calculator
The room heat loss in Btu/hr that this calculator starts from - See the calculator
Chimney Draft Calculator
Draft for the flue of an oil or gas boiler - See the calculator
Electrical Cable Calculator
Wire size for the circuit that feeds electric baseboard - See the calculator
Distribution Board Calculator
Panel space and breakers for new heating circuits - See the calculator
Heat Pump COP Calculator
Efficiency when a heat pump supplies the hot water - See the calculator
Electricity Bill Calculator
What the watts of electric baseboard cost to run - See the calculator
Insulation Calculator
Cut the heat loss, and the baseboard needed, before buying - See the calculator