Walls, windows, attic, floor and air leakage in; design heat loss in Btu per hour out, split line by line so you can see which upgrade cuts the most before sizing a furnace or heat pump.
Heat Loss Calculator - Btu/hr for a Room or House
Walls, windows, attic, floor and air leakage in; design heat loss in Btu per hour out, split line by line so you can see which upgrade cuts the most before sizing a furnace or heat pump.
Parameters
Enter data for calculations
💡 Fill in all required fields to unlock the calculate button
Heat loss in Btu per hour, line by line
Describe the walls, windows, ceiling, floor and air leakage of a room or a whole house, set the indoor and outdoor design temperatures, and this heat loss calculator adds up how many Btu per hour escape on the coldest design day. It shows which surface loses the most, so you can see whether a furnace upgrade, new windows or attic insulation buys more.
Quick start: a 1,500 sq ft one-story house, 8 ft ceilings, 160 ft of outside wall, 2x4 walls with batts, 180 sq ft of clear double-pane windows, two doors (40 sq ft), R-30 attic, floor over an unheated crawlspace, average airtightness (0.5 air changes per hour), 70 F inside and 5 F outside. Result: 27,100 Btu/hr, which is 18.1 Btu/hr per sq ft or 7.94 kW.
Measuring up before you start
- Floor area and ceiling height - heated square feet and the height in feet. Together they give the air volume for the leakage line.
- Outside wall length - feet of wall that faces outdoors. For a whole rectangular house this is the perimeter; for one room, only its outside walls. On a slab it is also the slab edge.
- Windows and doors - glass area in square feet (a 3 x 5 ft window is 15 sq ft) and door area (a standard 3 x 6.7 ft door is about 20 sq ft). If the window label lists an NFRC U-factor, type it in.
- Wall, ceiling and floor - pick the closest construction. Each choice carries a published U-factor, shown in the result.
- Airtightness - 0.35, 0.5, 1 or 1.5 air changes per hour, from a tight new house to a drafty old one. A blower door test gives the real figure.
- Design temperatures - indoor (empty = 70 F) and the outdoor heating design temperature for your area, the cold your system should handle, not the record low.
Where the 27,100 Btu/hr in the quick start goes
The table splits the example house into the six lines the result shows. The leakage line is the largest, and the windows lose more than the walls despite having a sixth of their area.
| Line | Arithmetic (65 F difference) | Btu/hr |
|---|---|---|
| Walls | 0.067 x 1,060 sq ft net x 65 | 4,616 |
| Windows | 0.53 x 180 x 65 | 6,201 |
| Doors | 0.45 x 40 x 65 | 1,170 |
| Ceiling | 0.036 x 1,500 x 65 | 3,510 |
| Floor | 0.047 x 1,500 x 65 | 4,583 |
| Air leakage | 0.018 x 0.5 x 12,000 cu ft x 65 | 7,020 |
Ten houses and rooms run through the calculator
Unless a line says otherwise, each one is the quick start house with a single change, so you can read off what that change is worth.
35,438 Btu/hr. Heat loss rises in a straight line with the temperature difference.
18,761 Btu/hr for the same house.
24,409 Btu/hr, about 2,700 less.
25,930 Btu/hr: the R-30 attic was already decent, so the gain is 1,170.
34,120 Btu/hr, 7,020 more than the quick start.
36,264 Btu/hr: empty 2x4 cavities triple the wall line.
Uninsulated walls, single-pane wood windows, R-19 attic, slab, 1.5 air changes: 71,496 Btu/hr, 47.7 per sq ft.
2x6 with board, low-e gas-filled glass, attic and floor at IECC levels, 0.35 air changes: 19,940 Btu/hr, 13.3 per sq ft.
27 ft of 2x6 outside wall, 24 sq ft of low-e glass, heated rooms above and below, 10 F: 1,734 Btu/hr.
400 sq ft, 60 ft of bare 2x4 wall, bare roof deck, slab, 1.5 air changes, 10 F outside: 19,179 Btu/hr.
The U-factors behind each choice
A U-factor is the heat in Btu per hour that passes through one square foot for each degree F of difference, so lower is better and U = 1 / R for a whole assembly. These are the values the form uses, with the source for each group.
| Part | Choices and U-factor | Source |
|---|---|---|
| Walls | 2x4 bare 0.20; 2x4 batts 0.067; plus 1 in. foam 0.056; 2x6 batts 0.043; 2x6 with board 0.036 | Engineering ToolBox stud wall R-values |
| Windows | single wood frame 0.83; single metal 1.02; clear double 0.53; low-e 0.32; low-e with gas 0.27; code maximum 0.30 | Engineering ToolBox; IECC zones 3-8 |
| Doors | metal sheet 1.2; 1 in. wood 0.65; 2 in. wood 0.45 | Engineering ToolBox |
| Ceiling | bare roof deck 0.5; attic R-19 0.049; R-30 0.036; code zones 2-3 0.026; zones 4-8 0.024 | Engineering ToolBox; Seattle Energy Code defaults; IECC |
| Floor | over unheated space 0.047 (zones 3-4) or 0.033 (zones 5-6); uninsulated slab F-0.73 per foot of edge | IECC; ASHRAE 90.1 slab table |
Slabs lose most of their heat at the edge, so they are counted per foot of exposed perimeter, not per square foot. Air leakage uses 0.018 Btu per cubic foot per degree, the heat it takes to warm a cubic foot of air by one degree.
From Btu per hour to a heating system
The total is what the heating system must replace at the design temperature, so it is the starting point for a furnace, boiler, heat pump or baseboard size. Run it room by room to size radiators or baseboard, and for the whole house to size the central unit. A furnace rated by input loses part of it up the flue: a 90% furnace with a 30,000 Btu/hr output needs about 33,300 Btu/hr of input. Contractors confirm sizes with ACCA Manual J, which adds duct losses and treats each room separately.
Heat loss questions from homeowners
Related tools
Baseboard Heat Calculator
Feet of hot water or electric baseboard for a room from its heat loss - See the calculator
Chimney Draft Calculator
Draft in inches of water column for a wood stove, fireplace, oil or gas flue - See the calculator
Insulation Calculator
How much insulation the walls or attic need - See the calculator
Air Conditioner Size Calculator
The cooling side of the same house, in Btu and tons - See the calculator
Gas vs Electric Heating Calculator
What the heat loss costs to replace with gas or electricity - See the calculator
Heat Pump COP Calculator
Efficiency of a heat pump at a given outdoor temperature - See the calculator
Gas Bill Calculator
Monthly gas cost from usage and rates - See the calculator
House Building Cost Calculator
Budget for a new build, insulation and windows included - See the calculator